{"id":2047,"date":"2026-10-28T13:19:26","date_gmt":"2026-10-28T10:19:26","guid":{"rendered":"https:\/\/tekknow.kz\/?post_type=product&#038;p=2047"},"modified":"2026-11-05T14:46:12","modified_gmt":"2026-11-05T11:46:12","slug":"additel-adt151-%d1%81%d0%bc%d0%b5%d0%bd%d0%bd%d1%8b%d0%b5-%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-%d0%b4%d0%b0%d0%b2%d0%bb%d0%b5%d0%bd%d0%b8%d1%8f","status":"publish","type":"product","link":"https:\/\/tekknow.kz\/en\/product\/additel-adt151-%d1%81%d0%bc%d0%b5%d0%bd%d0%bd%d1%8b%d0%b5-%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-%d0%b4%d0%b0%d0%b2%d0%bb%d0%b5%d0%bd%d0%b8%d1%8f\/","title":{"rendered":"Additel ADT151 Interchangeable Pressure Modules"},"content":{"rendered":"<p>Additel 151 (ADT151) is a series of precision interchangeable internal pressure modules designed specifically for the Additel 773, Additel 783 and Additel 793 automatic pressure controllers.<\/p>\n<p>Each ADT151 module has a precision silicon sensor and an individual digital temperature-compensation system. High-pressure modules support dual-range calibration: one module covers two independent measurement subranges while maintaining maximum accuracy in each. Three accuracy classes are available: 0.02% FS, 0.01% FS and 0.01% of reading (RD).<\/p>\n<p>Key Highlights:<br \/>\n\u2022 Fast replacement in 30 seconds: installs in the controller\u2019s top bay without cables or tools.<br \/>\n\u2022 Two ranges in one module: significant savings across a sensor fleet while expanding calibration capabilities.<br \/>\n\u2022 Enhanced safety: the controller automatically releases residual pressure when the bay latch is opened.<br \/>\n\u2022 Nonvolatile memory: all calibration coefficients are stored in the module, so the instrument is ready immediately after installation.<\/p>\n<p><iframe title=\"Introducing Additel&amp;apos;s New High Speed Pressure Controllers\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/woQSlq2MDzg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>","protected":false},"excerpt":{"rendered":"<p><strong>Pressure range:\u00a0<\/strong>From low pressures up to 15,000 psi (1,035 bar)<\/p>\n<p><strong>Accuracy:<\/strong> \u2022 0,02 % FS<br \/>\n\u2022 0.01% FS<br \/>\n\u2022 0.01% of reading (RD)<\/p>\n<p><strong>\u0414\u0432\u0443\u0445\u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u043d\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u043d\u0435\u043d\u0438\u0435: <\/strong>\u041a\u0430\u0436\u0434\u044b\u0439 \u043c\u043e\u0434\u0443\u043b\u044c ADT151 \u0441\u043e\u0434\u0435\u0440\u0436\u0438\u0442 2 \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u044b\u0445 \u043a\u0430\u043b\u0438\u0431\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0430 (High\/Low) \u0434\u043b\u044f \u0434\u0432\u0443\u043a\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0440\u0430\u0441\u0448\u0438\u0440\u0435\u043d\u0438\u044f \u0442\u043e\u0447\u043d\u043e\u0441\u0442\u0438<\/p>\n<p><strong>Temperature compensation: <\/strong>\u041f\u043e\u043b\u043d\u0430\u044f \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u0430\u044f \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u044f \u0432\u043e \u0432\u0441\u0435\u043c \u0440\u0430\u0431\u043e\u0447\u0435\u043c \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u0435<\/p>\n<p><strong>\u0421\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u0437\u0430\u043c\u0435\u043d\u044b: <\/strong>\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u0438\u043b\u0438 \u0437\u0430\u043c\u0435\u043d\u0430 \u0432 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u0430\u0445 ADT773\/783\/793 \u043c\u0435\u043d\u0435\u0435 \u0447\u0435\u043c \u0437\u0430 30 \u0441\u0435\u043a\u0443\u043d\u0434 \u0431\u0435\u0437 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u043e\u0432<\/p>\n<p><strong>\u0411\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u044c: <\/strong>Automatic pressure venting when the controller service door is opened before module removal<\/p>","protected":false},"featured_media":2048,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[20],"product_cat":[17,28],"product_tag":[],"class_list":["post-2047","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-pressure","product_cat-pressure-modules","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/product\/2047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/comments?post=2047"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/media\/2048"}],"wp:attachment":[{"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/media?parent=2047"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/product_brand?post=2047"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/product_cat?post=2047"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tekknow.kz\/en\/wp-json\/wp\/v2\/product_tag?post=2047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}