Additel ADT875 Standard Dry Well Calibrator

Temperature range: ADT875-155: −40 °C … 155 °C (at an ambient temperature of 23 °C)
ADT875-350: 33 °C … 350 °C
ADT875-660: 33 °C … 660 °C

Accuracy: ADT875-155: ±0.18 °C FS
ADT875-350: ±0,2 °C FS
ADT875-660: ±0,3 °C FS

Stability: ±0.01 °C (ADT875-155)
±0,015 °C (ADT875-350)
±0,03 °C (ADT875-660)

Uniformity: Axial (over 40 mm): ±0.05 °C (155), ±0.10 °C (350), ±0.15 °C (660)
Radial: ±0.015 °C (155), ±0.02 °C (350), ±0.03 °C (660)

Tank dimensions and capacity: Immersion depth: 160 mm; insert diameter: 30 mm; supports short probes (Short Probe Kit)

Dimensions and weight: 310 × 200 × 335 mm; weight: 10.8 to 12.5 kg

Process calibrator (PC option): 3 measurement channels:
• PRT reference resistance thermometer input
• 2 universal channels for test sensors (mA, V, RTD, TC, relay)
• 24 V loop power supply, HART protocol, task creation and documentation

TEKKNOW

Request a callback

Contact us for a free consultation and a quote for our services.

    If you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial and axial uniformity, and loading with speed, ruggedness and portability.

    Each unit features a color touchscreen display, dual-zone temperature control, and a Process Calibrator (PC) option that combines a fully functional documenting HART process calibrator with the temperature dry well. With the PC option, users can measure a reference PRT and two devices under test (DUT) channels simultaneously (measuring mA, voltage, switch, RTD, or thermocouple). In addition, users can configure and calibrate HART transmitters, execute automated task routines, log data with ramp and auto-step functions, and capture screen snapshots at the touch of a button.

    Unique Features:
    • CYOR Option (Choose Your Own Range): When purchasing, select your specific upper and lower temperature limits within the model range, and Additel calibrates and optimizes the dry well's performance specifically over your chosen band.
    • Self-Calibration Feature: Automated traceable self-calibration of internal control sensors using an external reference PRT eliminates long-term drift.
    • Short Probe Kit: The Additel 110 series short probe calibration kit allows users of the ADT875-155 (-40°C dry well) to calibrate challenging short-length probes and sanitary transmitters reliably.
    • Accredited Calibration: Includes an ISO 17025 accredited calibration certificate with full test data.

    Model

    ADT875

    Range

    −40 °C … 155 °C

    ,

    33 °C … 350 °C

    ,

    33 °C … 660 °C

    Accuracy

    ±0,18 °C

    ,

    ±0,2 °C

    ,

    ±0,3 °C

    Uniformity

    Осевая (на 40 мм): ±0,05 °C (155), ±0,10 °C (350), ±0,15 °C (660)

    ,

    Radial: ±0.015 °C (155), ±0.02 °C (350), ±0.03 °C (660)

    Size and volume

    Insertion depth: 160 mm; insert diameter: 30 mm

    Dimensions

    310 × 200 × 335 mm

    Weight

    12.5 kg

    We offer automatic pressure calibrators, digital pressure gauges, pressure calibration pumps, and multifunctional process calibrators

    DataSheet 875_Dry_Well_Calibrators