Electrical signals

Showing 1–12 of 53 results

In stock

Overvoltage protection
30 V DC (240 V AC)
Voltage limit
30 V between terminals or between terminals and ground
Measurement functions
Auto step, auto ramp, range step
Loop power supply
24 V

In stock

Model
ADT209, ADT210
Accuracy
ADT209: 0.03% of reading (RD); ADT210: 0.01% of reading (RD)
Range
DC voltage measurement from 0 to 30 V (accuracy 0.005 V)
Relay test
Testing the trip points of pressure and level switches

In stock

Model
1000A
DCV voltage
0 … ±1,000 V, accuracy: ±0.08%
ACV voltage
1 mV … 1,000 V (10 Hz … 40 kHz); accuracy: ±0.08%
DCI current
0 … ±10 A; accuracy: ±0.05%, up to 500 A with an external current coil EA002

In stock

Model
1000B
DCV voltage
0 … ±1,000 V, accuracy 0,005%
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.045%
DCI current
0 … ±10 A; accuracy of ±150 ppm (0.015%), up to 500 A with an external current coil EA002

In stock

Model
2090
Resistance
0 Ω – 99.9999 kΩ (passive decade output, ±0.1% / ±0.01% option)
Power Rating
1 Watt
Communication
RS-232 (optional USB-to-RS232 adapter), front panel keys

In stock

Model
3000AC
ACV voltage
Calculable AC voltage reference source with ~10 ppm accuracy
Frequency
Fixed frequencies up to 1 kHz
Traceability
Traceable to 4–10 ppm DC voltage multimeters

In stock

Model
3000CS
DCI current
4-shunt array covering 10 mA to 10 A (1-year stability up to 5 ppm)
Temperature Coefficient
< 0,6 ppm/°C
Temperature Monitoring
Built-in 4-wire Pt100 sensor output

In stock

Model
3000HR
Resistance
Decade values 1 MΩ – 100 GΩ (traceable to 1 GΩ standard)
DCI current
Electrometer currents down to 10 nA
Communication
RS-232 interface for automated decade switching

In stock

Model
3000RS
Resistance
Decade standard 1 Ω – 10 MΩ (< 5 ppm/year stability)
Temperature Coefficient
As low as 0.1 ppm/°C
Construction
4-wire hermetically sealed oil-filled resistors (no external oil/air bath needed)

In stock

Model
3000ZR
DCV voltage
4 independent banks of 10 V and 1.018 V (< 2 ppm/year stability)
Channels
4 independent temperature-controlled Zener banks
Battery Backup
Internal rechargeable battery backup for live transport

In stock

Model
3010A
DCV voltage
0 … ±1,000 V, accuracy ±100 ppm (0.01 per cent)
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.05%
DCI current
0 … ±30 A, accuracy of ±0.02%, up to 1,500 A with the EA002 current coil

In stock

Model
3041A
DCV voltage
0 … ±1,000 V, 0 … ±1000 V; basic accuracy over 1 year of ±25 ppm (0.0025%)
ACV voltage
1 mV … 1,000 V (10 Hz … 500 kHz), accuracy ±0.035%
DCI current