Temperature
Filter
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
Showing 1–12 of 27 results
Sort by
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
In stock
- Model
- AM1210
- Range
- 0 °C … 1300 °C
- Stability
- <0,1 °C при точке цинка (419,527 °C), <0,2 °C при точке затвердевания меди (1084,62 °C)
- Dimensions
- Наружный диаметр 6,0 мм (0,24"); стандартная длина 500 мм (20") или 600 мм (опция)
In stock
- Model
- AM1612A
- Range
- −200 °C … 160 °C
- Stability
- долговременный дрейф <0,04 °C в ТТВ после 100 ч при 160 °C, Кратковременная стабильность <0,02 °C
- Hysteresis
- ≤0,01 °C
In stock
- Model
- AM16XX
- Range
- AM1640: −200 °C … 420 °C, AM1660: −200 °C … 670 °C
- Accuracy
- <0.035 °C at 0 °C
- Stability
- долговременный дрейф <0,03 °C после 100 ч при max температуре, Кратковременная стабильность <0,01 °C
In stock
- Model
- AM1710
- Range
- −40 °C … 160 °C
- Stability
- долговременный дрейф <0,01 °C в ТТВ после 100 ч при 160 °C, Кратковременная стабильность <0,007 °C
- Hysteresis
- ≤0,005 °C
In stock
- Model
- AM1730
- Range
- −200 °C … 420 °C
- Stability
- долговременный дрейф <0,01 °C в ТТВ после 100 ч при 420 °C, Кратковременная стабильность <0,007 °C
- Hysteresis
- ≤0,005 °C
In stock
- Model
- AM1751
- Range
- −200 °C … 670 °C
- Stability
- долговременный дрейф <0,01 °C в ТТВ после 100 ч при 661 °C, Кратковременная стабильность <0,007 °C
- Hysteresis
- ≤0,005 °C
In stock
- Model
- AM176X
- Range
- −200 °C … 670 °C
- Accuracy
- ±0.006 °C at 0.01 °C, ±0.010 °C at −196 °C, ±0.015 °C at 420 °C, ±0.025 °C at 661 °C
- Stability
- дрейф в ТТВ <0,004 °C (4 мК) после 100 ч при 661 °C, Кратковременная нестабильность <0,002 °C
Temperature, Calibration equipment, Precision temperature measuring instruments, Reference resistance thermometers
In stock
- Model
- ADT282
- Accuracy
- ±0.006 °C (at 0 °C), ±0.009 °C (at 100 °C), From ±0.005 °C (−200…−40 °C)
- Range
- ±25 ppm RD (20…400 Ω), −10 … 75 mV; accuracy: ±(50 ppm RD + 2 µV), 0 … 400 Ω; accuracy: ±0.5 mΩ (0…20 Ω)
- Protection/Application area
- IP67
Temperature, Calibration equipment, Precision temperature measuring instruments, Reference resistance thermometers
In stock
- Model
- ADT286
- Accuracy
- 1 ppm (channel 1 with external reference Rs), up to 15 ppm (0.35 mΩ at 100 Ω)
- Датчики
- SPRTs, RTDs (PRTs: Pt100, Pt25, Pt10, Cu, Ni), thermistors, 15 types of thermocouples (S, R, B, K, N, E, J, T, etc.)
- Features
- 2 basic precision channels (CH1/CH2); expandable to 82 channels using scanning modules (up to 10 ch/s), 8½-digit DC multimeter (DC voltage from 100 nV, current, resistance), Zero-power measurement function
In stock
- Model
- ADT835
- Range
- -30 °C … 150 °C, 33 °C … 250 °C
- Accuracy
- ±0.1 °C across the entire heating and cooling range
- Uniformity
- Axial: ±0.02 °C (within 40 mm of the bottom); radial: ±0.01 °C
In stock
- Model
- ADT850-1200
- Range
- 100 °C … 1210 °C
- Uniformity
- Axial uniformity: ±0.25 °C over 60 mm at 1,200 °C; radial: ±0.25 °C at 1,200 °C
- Dimensions
- 680 × 330 × 450 mm
Load more products
Loading...





