Catalog
Filter
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
Showing 109–120 of 192 results
Sort by
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
In stock
- Model
- 3000AC
- ACV voltage
- Calculable AC voltage reference source with ~10 ppm accuracy
- Frequency
- Fixed frequencies up to 1 kHz
- Traceability
- Traceable to 4–10 ppm DC voltage multimeters
In stock
- Model
- 3000CS
- DCI current
- 4-shunt array covering 10 mA to 10 A (1-year stability up to 5 ppm)
- Temperature Coefficient
- < 0,6 ppm/°C
- Temperature Monitoring
- Built-in 4-wire Pt100 sensor output
In stock
- Model
- 3000HR
- Resistance
- Decade values 1 MΩ – 100 GΩ (traceable to 1 GΩ standard)
- DCI current
- Electrometer currents down to 10 nA
- Communication
- RS-232 interface for automated decade switching
In stock
- Model
- 3000RS
- Resistance
- Decade standard 1 Ω – 10 MΩ (< 5 ppm/year stability)
- Temperature Coefficient
- As low as 0.1 ppm/°C
- Construction
- 4-wire hermetically sealed oil-filled resistors (no external oil/air bath needed)
In stock
- Model
- 3000ZR
- DCV voltage
- 4 independent banks of 10 V and 1.018 V (< 2 ppm/year stability)
- Channels
- 4 independent temperature-controlled Zener banks
- Battery Backup
- Internal rechargeable battery backup for live transport
In stock
- Model
- 3010A
- DCV voltage
- 0 … ±1,000 V, accuracy ±100 ppm (0.01 per cent)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.05%
- DCI current
- 0 … ±30 A, accuracy of ±0.02%, up to 1,500 A with the EA002 current coil
In stock
- Model
- 3041A
- DCV voltage
- 0 … ±1,000 V, 0 … ±1000 V; basic accuracy over 1 year of ±25 ppm (0.0025%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 500 kHz), accuracy ±0.035%
- DCI current
- 0 … ±30 A, accuracy of ±50 ppm (0.005%), up to 1,500 A with the EA002 current coil
In stock
- Model
- 3050A
- DCV voltage
- 0 … ±1,000 V, basic accuracy over 1 year of ±50 ppm (0.005%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.04%
- DCI current
- 0 … ±30 A, accuracy of ±100 ppm (0.01%), up to 1,500 A with the EA002 current coil
In stock
- Model
- 3200B / 9200B
- ACV voltage
- 100 V – 400 V (±0.2%)
- Resistance
- Insulation 0 Ω – 2 GΩ (±0.3% / ±0.1% opt); loop/continuity 0.2 Ω – 1 kΩ
- PAT Earth Bond
- 0.05 Ω – 1 kΩ (±0.5%); current 100 mA – 30 A (±1.5%)
In stock
- Model
- 3200C / 9200C
- ACV voltage
- 100 V – 400 V (±0.2%)
- Resistance
- Insulation 0 Ω – 2 GΩ (up to 100 GΩ option; ±0.3% / ±0.1% opt)
- PAT Earth Bond
- 0.05 Ω – 1 kΩ (±0.5%); current 100 mA – 30 A (±1.5%)
In stock
- Model
- 3310A
- DCV voltage
- DC voltage 0 … 20 V DC with a basic error of ±100 ppm (0.01%)
- Опция HV
- Extension of the range up to 1,000 V DC
- Опция АС
- Reproduction of ACV (10 Hz … 100 kHz) and ACI
In stock
- Model
- 3341A
- DCV voltage
- 0 … 20 В DC с эталонной погрешностью от ±25 ppm (0,0025%)
- High-voltage unit:
- Option to extend the range from 20 V to 1,000 V DC
- Current module
- Low-current module 0 … 200 mA and high-current module 200 mA … 30 A (up to 1,500 A with a coil)
Load more products
Loading...