Multifunction calibrators

Showing all 12 results

In stock

Model
1000A
DCV voltage
0 … ±1,000 V, accuracy: ±0.08%
ACV voltage
1 mV … 1,000 V (10 Hz … 40 kHz); accuracy: ±0.08%
DCI current
0 … ±10 A; accuracy: ±0.05%, up to 500 A with an external current coil EA002

In stock

Model
1000B
DCV voltage
0 … ±1,000 V, accuracy 0,005%
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.045%
DCI current
0 … ±10 A; accuracy of ±150 ppm (0.015%), up to 500 A with an external current coil EA002

In stock

Model
3010A
DCV voltage
0 … ±1,000 V, accuracy ±100 ppm (0.01 per cent)
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.05%
DCI current
0 … ±30 A, accuracy of ±0.02%, up to 1,500 A with the EA002 current coil

In stock

Model
3041A
DCV voltage
0 … ±1,000 V, 0 … ±1000 V; basic accuracy over 1 year of ±25 ppm (0.0025%)
ACV voltage
1 mV … 1,000 V (10 Hz … 500 kHz), accuracy ±0.035%
DCI current
0 … ±30 A, accuracy of ±50 ppm (0.005%), up to 1,500 A with the EA002 current coil

In stock

Model
3050A
DCV voltage
0 … ±1,000 V, basic accuracy over 1 year of ±50 ppm (0.005%)
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.04%
DCI current
0 … ±30 A, accuracy of ±100 ppm (0.01%), up to 1,500 A with the EA002 current coil

In stock

Model
3310A
DCV voltage
DC voltage 0 … 20 V DC with a basic error of ±100 ppm (0.01%)
Опция HV
Extension of the range up to 1,000 V DC
Опция АС
Reproduction of ACV (10 Hz … 100 kHz) and ACI

In stock

Model
3341A
DCV voltage
0 … 20 В DC с эталонной погрешностью от ±25 ppm (0,0025%)
High-voltage unit:
Option to extend the range from 20 V to 1,000 V DC
Current module
Low-current module 0 … 200 mA and high-current module 200 mA … 30 A (up to 1,500 A with a coil)

In stock

Model
3350A
DCV voltage
0 … 20 V DC with an accuracy of ±50 ppm (0.005%)
Current module
Low-current module 0 … 200 mA and high-current module 200 mA … 22 A (AC/DC)
Resistance
0 ohms to 100 MΩ (accuracy: ±20 ppm)

In stock

Model
4610A
DCV voltage
0 … ±1025 В, прецизионный эталонный класс точности
ACV voltage
2 мВ … 1000 В (10 Гц … 1 МГц), расширенная широкополосная генерация
DCI current
0 … 30 А, up to 1,500 A with the EA002 current coil

In stock

Model
4610M
DCV voltage
0 … ±1,000 V, прецизионный эталонный класс точности
ACV voltage
1 мВ … 1000 В (10 Гц … 1 МГц)
AC/DC Current
Токовые диапазоны до 30 А (до 1500 А с внешними токовыми катушками)

In stock

Model
9041A
DCV voltage
0 … ±1,000 V, эталонная погрешность за 1 год от ±25 ppm (0,0025%)
ACV voltage
1 mV … 1,000 V (10 Hz … 500 kHz); accuracy: ±0.035%
DCI current
0 … ±30 A, accuracy of ±50 ppm (0.005%), up to 1,500 A with the EA002 current coil

In stock

Model
9050A
DCV voltage
0 … ±1,000 V, basic accuracy over 1 year of ±50 ppm (0.005%)
ACV voltage
1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.04%
DCI current
0 … ±30 A, accuracy of ±100 ppm (0.01%), up to 1,500 A with the EA002 current coil