Multifunction calibrators
Filter
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
Showing all 12 results
Sort by
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
In stock
- Model
- 1000A
- DCV voltage
- 0 … ±1,000 V, accuracy: ±0.08%
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 40 kHz); accuracy: ±0.08%
- DCI current
- 0 … ±10 A; accuracy: ±0.05%, up to 500 A with an external current coil EA002
In stock
- Model
- 1000B
- DCV voltage
- 0 … ±1,000 V, accuracy 0,005%
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.045%
- DCI current
- 0 … ±10 A; accuracy of ±150 ppm (0.015%), up to 500 A with an external current coil EA002
In stock
- Model
- 3010A
- DCV voltage
- 0 … ±1,000 V, accuracy ±100 ppm (0.01 per cent)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.05%
- DCI current
- 0 … ±30 A, accuracy of ±0.02%, up to 1,500 A with the EA002 current coil
In stock
- Model
- 3041A
- DCV voltage
- 0 … ±1,000 V, 0 … ±1000 V; basic accuracy over 1 year of ±25 ppm (0.0025%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 500 kHz), accuracy ±0.035%
- DCI current
- 0 … ±30 A, accuracy of ±50 ppm (0.005%), up to 1,500 A with the EA002 current coil
In stock
- Model
- 3050A
- DCV voltage
- 0 … ±1,000 V, basic accuracy over 1 year of ±50 ppm (0.005%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.04%
- DCI current
- 0 … ±30 A, accuracy of ±100 ppm (0.01%), up to 1,500 A with the EA002 current coil
In stock
- Model
- 3310A
- DCV voltage
- DC voltage 0 … 20 V DC with a basic error of ±100 ppm (0.01%)
- Опция HV
- Extension of the range up to 1,000 V DC
- Опция АС
- Reproduction of ACV (10 Hz … 100 kHz) and ACI
In stock
- Model
- 3341A
- DCV voltage
- 0 … 20 В DC с эталонной погрешностью от ±25 ppm (0,0025%)
- High-voltage unit:
- Option to extend the range from 20 V to 1,000 V DC
- Current module
- Low-current module 0 … 200 mA and high-current module 200 mA … 30 A (up to 1,500 A with a coil)
In stock
- Model
- 3350A
- DCV voltage
- 0 … 20 V DC with an accuracy of ±50 ppm (0.005%)
- Current module
- Low-current module 0 … 200 mA and high-current module 200 mA … 22 A (AC/DC)
- Resistance
- 0 ohms to 100 MΩ (accuracy: ±20 ppm)
In stock
- Model
- 4610A
- DCV voltage
- 0 … ±1025 В, прецизионный эталонный класс точности
- ACV voltage
- 2 мВ … 1000 В (10 Гц … 1 МГц), расширенная широкополосная генерация
- DCI current
- 0 … 30 А, up to 1,500 A with the EA002 current coil
In stock
- Model
- 4610M
- DCV voltage
- 0 … ±1,000 V, прецизионный эталонный класс точности
- ACV voltage
- 1 мВ … 1000 В (10 Гц … 1 МГц)
- AC/DC Current
- Токовые диапазоны до 30 А (до 1500 А с внешними токовыми катушками)
In stock
- Model
- 9041A
- DCV voltage
- 0 … ±1,000 V, эталонная погрешность за 1 год от ±25 ppm (0,0025%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 500 kHz); accuracy: ±0.035%
- DCI current
- 0 … ±30 A, accuracy of ±50 ppm (0.005%), up to 1,500 A with the EA002 current coil
In stock
- Model
- 9050A
- DCV voltage
- 0 … ±1,000 V, basic accuracy over 1 year of ±50 ppm (0.005%)
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.04%
- DCI current
- 0 … ±30 A, accuracy of ±100 ppm (0.01%), up to 1,500 A with the EA002 current coil





