Catalog

Showing 13–24 of 192 results

In stock

Model
ADT103
Range
Up to 15,000 psi (1,000 bar)
Connection
1/8", 1/4", 3/8", 1/2" NPT; 1/8", 1/4", 3/8", 1/2" BSP; M10×1.0, M14×1.5, M20×1.5
Material
High-strength stainless steel

In stock

Model
ADT104-HP
Range
15,000 psi (1,000 bar), 40,000 psi (2,800 bar) and 60,000 psi (4,200 bar), depending on the adapter
Connection
Выход на 15k psi: 1/4" NPT папа/мама; 1/2" NPT папа/мама; 1/4" BSP папа/мама; 1/2" BSP мама; 3/8" BSP мама; M14×1.5 мама; M20×1.5 мама, Выход на 40k psi: 3/8" BSP папа; 1/2" BSP папа; M14×1.5 папа; M20×1.5 папа, 60k psi outlet: 1/4HP male to 1/4HP male (3 couplings included)
Material
Special heat-resistant and high-strength stainless steel for ultra-high pressures

In stock

Model
ADT151
Range
From low pressures up to 15,000 psi (1,035 bar)
Accuracy
0.01% of reading (RD), 0.02% FS or 0.01% FS
Features
The ADT151 has two independent calibrated ranges (High/Low) to extend the accuracy range; automatic pressure venting when the controller service door is opened before removing the module

In stock

Model
ADT158Ex
Range
From vacuum and low pressures up to 4,200 bar (60,000 psi)
Accuracy
0.02% FS over the entire compensated temperature range
Features
Dedicated plug-in module for the ADT260Ex multichannel data logger and ADT273Ex calibrator

In stock

Model
ADT161
Range
From ±2.5 mbar (±1 inH₂O) to 4,200 bar (60,000 psi)
Accuracy
Up to 0.01% of reading (RD), 0.02% FS or 0.05% FS with full temperature compensation from −10 °C to 50 °C
Pressure type
Gauge, absolute, differential, vacuum and barometric

In stock

Model
ADT209, ADT210
Accuracy
ADT209: 0.03% of reading (RD); ADT210: 0.01% of reading (RD)
Range
DC voltage measurement from 0 to 30 V (accuracy 0.005 V)
Relay test
Testing the trip points of pressure and level switches

In stock

Model
ADT226, ADT226Ex
Accuracy
Differential pressure at high static pressure: 0.002% FS, Electrical error: 0.015 % of reading (RD) + 0.005 % of full scale (FS)
Features
pressure (via external ADT161/161Ex modules), Measurement, generation and simulation of electrical signals (mA, mV, V, frequency, pulses, resistance), temperature (TP thermocouples, TS resistance thermometers), Special applications: Leak and tightness testing, relief valve testing (10 readings per second), analogue sensor calibration, unit converter, thermocouple calculator
Power supply
Rechargeable Li-ion battery (up to 35 hours’ use)

In stock

Model
ADT227, ADT227Ex
Accuracy
Differential pressure at high static pressure: 0.002% FS, : Electrical basic error: 0.005 % of reading (RD) + 0.005% of full scale (FS)
Features
Built-in HART communicator (HART option):, Multi-channel data logger:, Direct measurement of True RMS alternating voltage up to ±300 V AC
Power supply
Rechargeable Li-ion battery (up to 35 hours’ use)

In stock

Model
ADT273Ex
Range
up to 4200 bar
Accuracy
0,02%, 0,05% FS
Communication
Bluetooth, HART (optional), USB