Additel ADT878 Reference Dry Well Calibrator

Temperature range: ADT878-160: −40 °C … 160 °C (at an ambient temperature of 23 °C)
ADT878-425: 33 °C … 425 °C
ADT878-700: 33 °C … 700 °C

Accuracy: ADT878-160: ±0.1 °C FS
ADT878-425: ±0,2 °C FS
ADT878-700: ±0.2 °C (up to 425 °C), ±0.25 °C (up to 700 °C)

Stability: ±0.005 °C (ADT878-160)
±0,01 °C (ADT878-425)
±0,02 °C (ADT878-700)

Uniformity: Axial (over 40 mm): ±0.025 °C (160), ±0.05 °C (425), ±0.08 °C (700)
Radial: ±0.01 °C (160), ±0.015 °C (425), ±0.025 °C (700)

Tank dimensions and capacity: Immersion depth: 160 mm; insert diameter: 30 mm; supports short probes (Short Probe Kit)

Dimensions and weight: 310 × 200 × 335 mm; weight: 10.8 to 12.5 kg

Special modes: ADT878-160: automatic implementation and maintenance of the triple point of water (TPW kit)
ADT878-700: Automated procedure for the high-temperature annealing of platinum resistance thermometers (PRT Annealing)

Process calibrator (PC option):

Built-in multi-channel meter:
• Reference resistance thermometer (PRT) channel
• 2 UUT channels (mA, V, RTD, TC, relay, 24 V power supply)
• Full-featured HART communicator and documentation

TEKKNOW

Request a callback

Contact us for a free consultation and a quote for our services.

    The Additel 878 Reference Dry Well Calibrators set a new standard for portable reference-level temperature calibration tools. Combining unmatched stability, radial and axial uniformity, and accuracy with fast thermal transitions, rugged construction, and field portability, the ADT878 delivers laboratory-grade performance wherever you need it.

    Each model includes a color touchscreen display, dual-zone temperature control, and a choice between a standard calibrator or an integrated Process Calibrator (PC) option. The PC option incorporates a multi-channel precision readout for a reference PRT and two devices under test (DUT), supporting mA, voltage, switch testing, RTDs, thermocouples, 24V loop power, task documentation, and full HART communication.

    Model Capabilities:
    • ADT878-160 (-40°C to 160°C): Features display accuracy of ±0.1°C. Supports the optional Additel 878-TPW kit to automatically realize and maintain a Triple Point of Water (TPW) cell, providing an on-board primary standard realization to verify reference probe drift.
    • ADT878-425 (33°C to 425°C): Features display accuracy of ±0.2°C at full range with exceptional thermal stability.
    • ADT878-700 (33°C to 700°C): Features display accuracy up to ±0.2°C and built-in automated PRT annealing procedures to relieve strain and restore stability to noble metal reference probes.

    Key Highlights:
    • Set point control by external reference PRT eliminates stem conduction errors.
    • Automated self-calibration feature allows traceable alignment of internal sensors using an external standard.
    • Quick-Push connectors (PC option) allow tool-free wiring of bare wires, spade lugs, and mini-plugs.

    Model

    ADT878

    Range

    −40 °C … 160 °C

    ,

    33 °C … 425 °C

    ,

    33 °C … 700 °C

    Accuracy

    ±0,1 °C

    ,

    ±0,2 °C

    ,

    ±0,2 °C (до 425 °C), ±0,25 °C (до 700 °C)

    Uniformity

    ±0,01 °C (160), ±0,015 °C (425), ±0,025 °C (700)

    ,

    Осевая (на 40 мм): ±0,025 °C (160), ±0,05 °C (425), ±0,08 °C (700)

    Size and volume

    Insertion depth: 160 mm; insert diameter: 30 mm

    Dimensions

    310 × 200 × 335 mm

    Weight

    12.5 kg

    We offer automatic pressure calibrators, digital pressure gauges, pressure calibration pumps, and multifunctional process calibrators

    DataSheet 878_Reference_Dry_Well_Calibrators