Process Moisture Analyzer — Michell Multi-Channel Process Monitor
Channels & Measured Parameters: Up to 6 independent measurement channels in any mix: moisture in gas (ppmV, dew point °C/°F, LBMMSCF, mg/m³), moisture in liquid, or oxygen (% / ppmV O2)
Display & Tagging: 7″ color touchscreen LCD displaying moisture/dew point or O2, analysis pressure/temperature, and configurable process tag names
Hazardous Area Interface: Integrated galvanic isolation I.S. barriers built into the monitor for connecting field Ex sensors
Analog & Digital Outputs: Three 4–20 mA (500 Ω max) per channel, user-configurable; RS485 Modbus RTU plus Ethernet port for Modbus TCP/IP
Data Logging & Alarms: SD card logging (up to 32 GB FAT16/FAT32) of all variables & fault codes; 2 Form C relays (30 V DC, 5 A) per channel + system alarm; NAMUR 102 indicators
Pressure Compensation & Resolution: Fixed programmed value or dynamic input from optional pressure sensor; resolution down to 0.001 ppmV, 0.1 °Cdp, 0.01 % / 0.5 ppmV O2
Power & Operating Environment: 85 to 264 V AC (47/63 Hz) or 20 to 28 V DC, 30 VA max; indoor safe area, 0 to +50 °C (+32 to +122 °F), <90 % RH
Chassis Dimensions & Wiring: 19″ sub-rack unit: 132×483×375 mm (5×19×14.75″), 100 mm rear clearance; screened twisted-pair field cable
Request a callback
Contact us for a free consultation and a quote for our services.
The Michell Multi-Channel Process Monitor is a flexible 6-channel industrial analyzer control unit delivering real-time, multi-parameter monitoring of moisture in high-pressure process gases, moisture in vaporized liquids, and oxygen (% / ppmV O2) for oil & gas, LNG, hydrogen production, and petrochemical plants.
Integrating galvanic isolation I.S. barriers directly inside a 19″ sub-rack chassis (132×483×375 mm), a single monitor accepts any combination of up to six independent PST moisture and O2 channels with fixed or dynamic pressure compensation.
Its bright 7″ color touchscreen LCD displays live readings with configurable process tag names and NAMUR 102 status indicators. Each channel includes three configurable 4–20 mA outputs and two Form C alarm relays, complemented by RS485 Modbus RTU, Ethernet Modbus TCP/IP, and SD-card datalogging up to 32 GB.
| Model |
Michell Multi-Channel Process Monitor |
|---|---|
| Range |
Up to 6 independent channels: moisture in gas/liquid & O2 (% / ppmV) |
| Accuracy |
Resolution down to 0.001 ppmV, 0.1 °Cdp, 0.01 % / 0.5 ppmV O2; dynamic P comp |
| Communication |
7″ touchscreen, 3× 4–20 mA/ch, RS485 Modbus RTU, Ethernet Modbus TCP/IP, 32 GB SD |
| Power supply |
85 to 264 V AC (47/63 Hz) or 20 to 28 V DC, 30 VA max |
| Protection/Application area |
Safe-area 19″ sub-rack (0 to +50 °C) with integrated galvanic I.S. barriers |
| Connection |
Screened twisted pair (1–2 pairs/ch), 132×483×375 mm |
| Features |
6 channels, NAMUR 102 alarms, 2 relays/ch, custom process tags, moisture + O2 |
Technical Documentation: Michell_Instruments_Multi-Channel_Process_Monitor_Datasheet