Process Moisture Analyzer — Michell Promet I.S.
Channels, Sensor & Pressure: 1 to 4 channels (Easidew PRO I.S. + ES70 cabinet, opt. Minox-i O2 / Liquidew I.S.); up to 45 MPa (450 barg / 6526.7 psig); up to 20 % H2 ready
Range & Accuracy: -100 to +20 °Cdp (NPL/NIST traceable); ±1 °C (-60 to +20 °Cdp) / ±2 °C (-60.1 to -100 °Cdp), ±10 % moisture content; resolution 0.1 °C
Pressure Option & Flow: Optional pressure sensor 0 to 138 barg (±0.25 % FS); sample flow 1 to 5 l/min; immune to H2S, mercaptans & glycol
Field Hazardous Area Approvals: ATEX/UKCA II 1 G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; TR CU 0Ex ia IIC T4 Ga (-20 to +70 °C); cQPSus Cl I Div 1 / Zone 0; GOST-R/K
Control Unit (Safe Area): 2.8″ color touchscreen LCD, integrated I.S. barriers, 19″ sub-rack (132×483×375 mm), 85–265 V AC or 20–28 V DC (30 VA max)
Outputs & Alarms: 3× 4–20 mA (500 Ω max), RS485 Modbus RTU, 4 programmable alarm relays (2 Form C + 2 Form A, 30 V DC, 5 A)
Sampling Cabinet (ES70): 304 SS (optional 316 SS), IP66, 800×600×300 mm, stainless brackets; optional 100 W heater (+20 °C or 0–50 °C) / cooler
Operating Environment: Sensor -40 to +60 °C; sampling cabinet -20 to +50 °C (-40 to +60 °C transient); indoor control unit 0 to +50 °C
Request a callback
Contact us for a free consultation and a quote for our services.
The Michell Promet I.S. Process Moisture Analyzer is a heavy-duty, intrinsically safe industrial hygrometer system engineered for high-pressure natural gas platforms, LNG terminals, pipeline custody transfer, and petrochemical processing at direct operating pressures up to 45 MPa (450 barg).
Pairing Easidew PRO I.S. ceramic metal-oxide sensors with custom-engineered ES70 IP66 stainless-steel sampling systems, it resists H2S, mercaptans, glycol carryover, and up to 20 % hydrogen. Calibrated from -100 to +20 °Cdp traceable to NPL and NIST (±1 °C from -60 to +20 °Cdp), multi-channel variants support up to 4 channels and optional O2 (Minox-i) or moisture-in-liquid (Liquidew I.S.) measurement.
The field hardware carries global Ex ia certifications (ATEX/UKCA/IECEx II 1 G Ex ia IIC T4 Ga, TR CU 0Ex ia, cQPSus Cl I Div 1, GOST-R/K), while the safe-area 19″ control unit houses integrated galvanic I.S. barriers, a 2.8″ color touchscreen, three 4–20 mA outputs, four alarm relays, and RS485 Modbus RTU.
| Model |
Michell Promet I.S. |
|---|---|
| Range |
-100 to +20 °Cdp; operating pressure up to 45 MPa (450 barg); up to 20 % H2 |
| Accuracy |
±1 °Cdp (-60 to +20 °Cdp) / ±2 °Cdp (-100 to -60 °Cdp); pressure ±0.25 % FS |
| Communication |
2.8″ LCD, 3× 4–20 mA, RS485 Modbus RTU, 4 alarm relays |
| Power supply |
85 to 265 V AC or 20 to 28 V DC (30 VA); optional heater 110/230 V AC (100 W) |
| Protection/Application area |
ATEX/IECEx/TR CU 0Ex ia IIC T4 Ga, cQPSus Cl I Div 1; IP66 304/316 SS cabinet |
| Connection |
ES70 sampling cabinet (800×600×300 mm) + 19″ rack unit (132×483×375 mm) |
| Features |
Up to 4 channels (incl. O2 / liquid moisture), H2S & glycol immune, 450 barg |
Technical Documentation: Michell_Instruments_Promet_IS_EN_Datasheet