Catalog
Filter
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
Showing 97–108 of 192 results
Sort by
Categories
- Pressure
- Temperature
- Liquid baths
- Precision temperature measuring instruments
- Temperature calibrators
- Fixed points and realization equipment
- Climatic chambers
- Thermometry bridges
- Cryogenic equipment
- Blackbody sources
- Cold-junction compensation equipment
- Reference resistance thermometers
- Reference thermocouples
- Calibration equipment
- Chemical composition
- Humidity
- Electrical signals
- Power analyzers
- Current measurement systems
- Precision bridges
- Voltage dividers
- Voltage, resistance, and frequency standards
- Precision current transformers
- Liquid and air baths for resistance standards
- Teraohmmeter
- Software
- Electrical signal calibrator
- Test equipment
- Reference multimeters
- Multifunction calibrators
- Current shunts
- Reference electricity meters
- Precision measurement systems
- Electricity meter verification systems
- Conductivity (salinity) standards
- Flow
Filter
In stock
- Model
- Michell S8000 -100
- Range
- -100 to +20 °C frost/dew point (to 13.8 ppbV); pressure up to 1.6 bara
- Accuracy
- ±0.1 °C; reproducibility ±0.15 °Cfp at -100 °Cfp; stability ±0.1 °C
- Communication
- 2× 0/4–20 mA, Modbus RTU (USB), opt. RS485/RS232/TCP Ethernet, 8 GB SD, 5.7″ LCD
In stock
- Model
- Michell S8000 HT
- Range
- -30 to +95 °C frost/dew point; pressure up to 0.5 barg
- Accuracy
- ±0.1 °C (±0.18 °F); stability & reproducibility ±0.05 °Cdp
- Communication
- 2× 0/4–20 mA, Modbus RTU (USB), Modbus TCP/IP (Ethernet/RS485), 8 GB SD, 5.7″ LCD
In stock
- Model
- Michell S8000 Remote
- Range
- -40 to +120 °Cdp (<0.5 to 100 % RH); pressure up to 20 barg (opt. 250 barg)
- Accuracy
- ±0.1 °C dew point & temperature (Pt100 1/10 DIN); reproducibility ±0.05 °C
- Communication
- 3× 4–20 mA / 0–1 V, Modbus RTU (USB/RS232/RS485) & TCP (Ethernet), SD card, 5.7″ LCD
In stock
- Model
- Michell S8000 RS
- Range
- -90 / -80 to +20 °C frost/dew point (to 95.4 ppbV); pressure up to 10 barg
- Accuracy
- ±0.1 °C; stability ±0.05 °C; reproducibility ±0.05 / ±0.025 °Cdp
- Communication
- 2× 0/4–20 mA, Modbus RTU (USB), Modbus TCP/IP (Ethernet), 8 GB SD, 5.7″ LCD
In stock
- Model
- Michell S8000
- Range
- -60 to +40 °Cdp; pressure 0 to 1 barg (LP) / 0 to 20 barg (HP)
- Accuracy
- ±0.1 °Cdp; reproducibility ±0.05 °C; optional Pt100 ±0.1 °C
- Communication
- 2× 4–20 mA / 0–1 V, Modbus RTU (USB), Modbus TCP (Ethernet), SD card, 5.7″ display
In stock
- Model
- Michell SF52
- Range
- -40 to +60 °Cdp (-40 to +140 °Fdp); scaled ranges: -40 to +60 °Cdp, -30 to +30 °Cdp, or absolute humidity 0 to 200 g/m³
- Accuracy
- ±2 °Cdp (±3.6 °Fdp); absolute humidity 0.4 to 3 g/m³; repeatability 0.5 °Cdp; stability <1 °C/year
- Communication
- 0 to 1 V, 0 to 5 V, 0 to 10 V, or 4–20 mA (3-wire); diagnostics: fault 23 mA, under-range 4 mA, over-range 20 mA
In stock
- Model
- Michell SF72 Rail
- Range
- -60 to +60 °Cdp (-76 to +140 °Fdp); key control points -50 to +10 °Cdp
- Accuracy
- ±2 °Cdp (±3.6 °Fdp); repeatability ±0.2 °Cdp; long-term stability <1%/year
- Communication
- 4 to 20 mA (2-wire current source); digital diagnostics: RS485 2-wire Modbus RTU; diagnostics: fault 23 mA, under-range 4 mA, over-range 20 mA
In stock
- Model
- Michell SF82 Online
- Range
- -60 to +60 °Cdp (-76 to +140 °Fdp); -50 to +50 °Cdp, -50 to +30 °Cdp; max scaled analog -80 to +20 °Cdp (ppmV on request)
- Accuracy
- ±2 °Cdp (±3.6 °Fdp) over compensated temperature range (-20 to +50 °C); repeatability 0.5 °Cdp
- Communication
- 4–20 mA or 0–20 mA; Modbus RTU over RS485; dual programmable relay alarms; diagnostics: 23 mA / 4 mA / 20 mA
In stock
- Model
- Michell SF82
- Range
- -60 to +60 °Cdp (-76 to +140 °Fdp); scaled 4–20 mA ranges incl. -60…+60, -50…+50, -50…+30, -80…+20, -20…+50 °Cdp or 0 to 24,000 ppmV
- Accuracy
- ±2 °Cdp (±3.6 °Fdp) over compensated temperature range (-20 to +50 °C); repeatability 0.5 °Cdp
- Communication
- 4 to 20 mA (2-wire current source); SF82 M12 adds Modbus RTU over RS485 (incl. temperature via Modbus)
In stock
- Model
- 1000A
- DCV voltage
- 0 … ±1,000 V, accuracy: ±0.08%
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 40 kHz); accuracy: ±0.08%
- DCI current
- 0 … ±10 A; accuracy: ±0.05%, up to 500 A with an external current coil EA002
In stock
- Model
- 1000B
- DCV voltage
- 0 … ±1,000 V, accuracy 0,005%
- ACV voltage
- 1 mV … 1,000 V (10 Hz … 100 kHz), accuracy ±0.045%
- DCI current
- 0 … ±10 A; accuracy of ±150 ppm (0.015%), up to 500 A with an external current coil EA002
In stock
- Model
- 2090
- Resistance
- 0 Ω – 99.9999 kΩ (passive decade output, ±0.1% / ±0.01% option)
- Power Rating
- 1 Watt
- Communication
- RS-232 (optional USB-to-RS232 adapter), front panel keys
Load more products