Additel

Showing 13–24 of 67 resultsSorted by average rating

In stock

Model
AM16XX
Range
AM1640: −200 °C … 420 °C, AM1660: −200 °C … 670 °C
Accuracy
<0.035 °C at 0 °C
Stability
долговременный дрейф <0,03 °C после 100 ч при max температуре, Кратковременная стабильность <0,01 °C

In stock

Model
ADT286
Accuracy
1 ppm (channel 1 with external reference Rs), up to 15 ppm (0.35 mΩ at 100 Ω)
Датчики
SPRTs, RTDs (PRTs: Pt100, Pt25, Pt10, Cu, Ni), thermistors, 15 types of thermocouples (S, R, B, K, N, E, J, T, etc.)
Features
2 basic precision channels (CH1/CH2); expandable to 82 channels using scanning modules (up to 10 ch/s), 8½-digit DC multimeter (DC voltage from 100 nV, current, resistance), Zero-power measurement function

In stock

Model
ADT282
Accuracy
±0.006 °C (at 0 °C), ±0.009 °C (at 100 °C), From ±0.005 °C (−200…−40 °C)
Range
±25 ppm RD (20…400 Ω), −10 … 75 mV; accuracy: ±(50 ppm RD + 2 µV), 0 … 400 Ω; accuracy: ±0.5 mΩ (0…20 Ω)
Protection/Application area
IP67

In stock

Model
ADT227, ADT227Ex
Accuracy
Differential pressure at high static pressure: 0.002% FS, : Electrical basic error: 0.005 % of reading (RD) + 0.005% of full scale (FS)
Features
Built-in HART communicator (HART option):, Multi-channel data logger:, Direct measurement of True RMS alternating voltage up to ±300 V AC
Power supply
Rechargeable Li-ion battery (up to 35 hours’ use)

In stock

Model
ADT226, ADT226Ex
Accuracy
Differential pressure at high static pressure: 0.002% FS, Electrical error: 0.015 % of reading (RD) + 0.005 % of full scale (FS)
Features
pressure (via external ADT161/161Ex modules), Measurement, generation and simulation of electrical signals (mA, mV, V, frequency, pulses, resistance), temperature (TP thermocouples, TS resistance thermometers), Special applications: Leak and tightness testing, relief valve testing (10 readings per second), analogue sensor calibration, unit converter, thermocouple calculator
Power supply
Rechargeable Li-ion battery (up to 35 hours’ use)

In stock

Model
ADT161
Range
From ±2.5 mbar (±1 inH₂O) to 4,200 bar (60,000 psi)
Accuracy
Up to 0.01% of reading (RD), 0.02% FS or 0.05% FS with full temperature compensation from −10 °C to 50 °C
Pressure type
Gauge, absolute, differential, vacuum and barometric

In stock

Model
ADT158Ex
Range
From vacuum and low pressures up to 4,200 bar (60,000 psi)
Accuracy
0.02% FS over the entire compensated temperature range
Features
Dedicated plug-in module for the ADT260Ex multichannel data logger and ADT273Ex calibrator

In stock

Model
ADT151
Range
From low pressures up to 15,000 psi (1,035 bar)
Accuracy
0.01% of reading (RD), 0.02% FS or 0.01% FS
Features
The ADT151 has two independent calibrated ranges (High/Low) to extend the accuracy range; automatic pressure venting when the controller service door is opened before removing the module

In stock

Model
ADT295
Communication
Full support for HART and FOUNDATION Fieldbus (FF) protocols
Power supply
Built-in 24 V DC loop power supply with switchable 250 Ω resistor
Device Description (DD) Library
Pre-installed DD/EDDL library with free updates over Wi-Fi

In stock

Model
ADT793
Range
Up to 15,000 psi (1,035 bar); pressure generation and precision automatic control
Accuracy
0.02% FS, 0.01% FS or 0.01% of reading (RD)
Stability
0.005% FS at pressures up to 15,000 psi

In stock

Model
ADT783
Range
From −0.99 to 6,420 bar
Accuracy
0.02% FS, 0.01% FS or 0.01% of reading (RD)
Stability
0.003% FS over the full range

In stock

Model
ADT773
Range
773-D: −380 to 2,500 inH₂O (−0.95 to 7 bar); 773-LLP: −380 to 400 inH₂O (−0.95 to 1 bar)
Accuracy
0.02% FS or 0.01% FS; for ultra-low-pressure modules: DP2/DP5 0.05% FS, DP10 0.02% FS
Stability
±(0,001…0,003) % FS