Model
Michell Easidew EA2
Range
-110 to +20 °Cdp (-166 to +68 °Fdp); -100 to +20 °Cdp; moisture content 0 to 3000 ppmV (non-standard ranges on request)
Accuracy
±2 °Cdp (±3.6 °Fdp) over compensated temperature range (-20 to +50 °C); repeatability 0.5 °Cdp
Communication
4 to 20 mA (2-wire current source, user configurable); Easidew M12: Modbus RTU over RS485

In stock

Model
Michell Easidew I.S.
Range
-100 to +20 °Cdp (-148 to +68 °Fdp) or -110 to +20 °Cdp (-166 to +68 °Fdp); moisture content 0 to 3000 ppmV
Accuracy
±2 °Cdp (±3.6 °Fdp) over compensated temperature range (-20 to +50 °C); repeatability 0.5 °Cdp
Communication
4 to 20 mA (2-wire loop-powered, current source, user configurable); diagnostics: fault 23 mA, under-range 4 mA, over-range 20 mA

In stock

Model
Michell Easidew Online
Range
-110 to +20 °Cdp (-166 to +68 °Fdp) or -100 to +20 °Cdp; moisture content 0 to 3000 ppmV
Accuracy
±2 °Cdp (±3.6 °Fdp) over compensated temperature range (-20 to +50 °C); repeatability 0.5 °Cdp
Communication
4–20 mA or 0–20 mA; Modbus RTU over RS485; dual programmable relay alarms; diagnostics: 23 mA / 4 mA / 20 mA

In stock

Model
Michell Easidew PDP Dryer Portable
Range
-100 to +20 °Cdp (EA-PDP-B1) / -60 to +60 °Cdp (EA-PDP-B2); pressure up to 20 barg
Accuracy
±2 °Cdp (±3.6 °Fdp); repeatability 0.5 °Cdp
Communication
3.5″ LCD touchscreen (640×480), graphing, 2 GB SD card, USB-C (.TXT)

In stock

Model
Michell Easidew PRO I.S.
Range
Gases (PRO I.S.): -110 to +20 °Cdp or -100 to +20 °Cdp, 0 to 3000 ppmV (non-std mg/m³
Accuracy
±1 °Cdp (+20 to -60 °Cdp); ±2 °Cdp (-60 to -110 °Cdp) over -20 to +50 °C; repeatability 0.5 °Cdp
Communication
4 to 20 mA (2-wire current source, user configurable); diagnostics: fault 23 mA, under-range 4 mA, over-range 20 mA

In stock

Model
Michell Easidew PRO XP
Range
Gases (PRO XP): -110 to +20 °Cdp or -100 to +20 °Cdp, 0 to 3000 ppmV (non-std mg/m³
Accuracy
±1 °Cdp (+20 to -60 °Cdp); ±2 °Cdp (-60 to -110 °Cdp) over -20 to +50 °C; repeatability 0.5 °Cdp
Communication
4 to 20 mA (2-wire current source); secondary RS485 for re-ranging; optional integral 4-digit LED display (-1999 to +9999)

In stock

Model
Michell Easidew Sampler (EA2-SAM)
Connection
5/8"-18 UNF port (accepts all Michell Easidew / SF82 impedance sensors and transmitters)
Features
Low-cost

In stock

Model
Michell ES20
Range
Range: -100 to +20 °Cdp or -110 to +20 °Cdp; accuracy up to ±1 °Cdp or ±2 °Cdp (depending on fitted transmitter)
Communication
Terminal rail (base plate) or M20 plastic cable glands (GRP/SS enclosures); optional 1/8 DIN monitor bracket
Power supply
230 V AC (vacuum pump option only; not available for ES20 PRO XP)

In stock

Model
Michell ES70
Range
Gas: 138 barg maximum; Liquid: 50 barg maximum
Power supply
Sensor: 14 to 28 V DC; Sampling system: 240 V AC or 110 V AC
Protection/Application area
Indoor open panel (750×750×2 mm) or Outdoor IP66 / NEMA 4X enclosure (304 or 316 SS, with/without window, 800×800×300 mm)

In stock

Model
Michell I.S. Field Display (EPD)
Communication
4 to 20 mA loop-powered; voltage drop <1.2 V @ 20 °C, <1.3 V @ -40 °C (<5 V with optional loop-powered green backlight)
Protection/Application area
ATEX: Group II Category 1GD Ex ia IIC T5 Ga (Ta = -40 to +70 °C) IECEx: Ex ia IIC T5 Ga (Tamb = -40 to +70 °C) UKCA FM: CL I, II, III Div 1 GP A
Features
4-digit loop-powered local monitor for Michell Easidew I.S. and Easidew PRO I.S. transmitters (order code EPD)

In stock

Model
Michell MDM300 / MDM300 I.S.
Range
-100 to +20 °Cdp (calibrated -70 to +20 / -100 to -70 °Cdp); pressure up to 350 barg
Accuracy
±1 °Cdp (-60 to +20 °Cdp); gas temp ±0.2 °C; 13-pt certificate
Communication
8 MB data logger (10,000 logs/file), Bluetooth 2.0 (up to 5 m), graphical LCD