Catalog

Showing 85–96 of 192 results

In stock

Model
Michell MDM300 Sampling Options
Range
Maximum sample pressure up to 300 barg (30 MPa); operating temperature -20 to +50 °C
Protection/Application area
AISI 316 stainless steel panel with Viton seals; optional protective transit case
Connection
Swagelok tube connectors, Rp 1/4″, DILO DN8/DN20 (SF6), Rectus quick-release, 2 m PTFE

In stock

Model
Michell Multi-Channel Process Monitor
Range
Up to 6 independent channels: moisture in gas/liquid & O2 (% / ppmV)
Accuracy
Resolution down to 0.001 ppmV, 0.1 °Cdp, 0.01 % / 0.5 ppmV O2; dynamic P comp
Communication
7″ touchscreen, 3× 4–20 mA/ch, RS485 Modbus RTU, Ethernet Modbus TCP/IP, 32 GB SD

In stock

Model
Michell Optidew (401 / 501)
Range
-40 to +120 °Cdp; 0.45 to 100 % RH; pressure up to 2500 kPa (25 bar)
Accuracy
±0.15 °C dew point; ±0.1 °C temperature; repeatability ±0.05 °C
Communication
2× 0/4–20 mA, Modbus RTU (RS485/USB), opt. Modbus TCP (Ethernet), SD card, 5.7″ display

In stock

Model
Michell OptiPEAK TDL600
Range
1 to 1000 ppmV (up to 100 barg); up to 20 % hydrogen
Accuracy
±1 ppmV or ±3 % of reading; repeatability ±0.5 ppmV or ±1.5 %
Communication
3× 4–20 mA out, 2× 4–20 mA in, RS485 Modbus RTU, 3 relays, 4.3″ LCD

In stock

Model
Michell Promet EExd
Range
-120 to +30 °Cdp (1 ppbV to 30,000 ppmV); pressure 30 to 138 barg
Accuracy
±1 °Cdp (-59.9 to +20 °Cdp) / ±2 °Cdp (-100 to -60 °Cdp); pressure ±0.25 % FS
Communication
Through-glass VFD, 2× 4–20 mA/ch, RS485 Modbus RTU, 2 relays/ch

In stock

Model
Michell Promet I.S.
Range
-100 to +20 °Cdp; operating pressure up to 45 MPa (450 barg); up to 20 % H2
Accuracy
±1 °Cdp (-60 to +20 °Cdp) / ±2 °Cdp (-100 to -60 °Cdp); pressure ±0.25 % FS
Communication
2.8″ LCD, 3× 4–20 mA, RS485 Modbus RTU, 4 alarm relays

In stock

Model
Michell Pura Online / Advanced Online 2
Range
-120 to -40 °Cdp (-184 to -40 °Fdp), down to 1 ppbV; 0 to 127 ppmV (ppmV, ppbV, lbs/MMscf, g/m³ on Advanced Online 2)
Accuracy
±1 °C (-40 to -60 °Cdp); ±2 °C (-60 to -100 °Cdp); ±4 °C (-100 to -120 °Cdp, extrapolated)
Communication
Pura Advanced Online 2 (5.5-digit touchscreen + live pressure compensation): 3 × 4–20 mA, Modbus RTU RS485

In stock

Model
Michell Pura
Range
-120 to -40 °Cdp (-184 to -40 °Fdp), down to 1 ppbV; moisture content 0 to 127 ppmV (non-standard ranges on request)
Accuracy
±1 °C (-40 to -60 °Cdp); ±2 °C (-60 to -100 °Cdp); ±4 °C (-100 to -120 °Cdp, extrapolated)
Communication
4–20 mA (2-wire current source or 3-wire current sink); Pura M12: Modbus RTU over RS485; PUR-AOL-SEN-D: Michell Mnet digital

In stock

Model
Michell QMA401
Range
0.1 to 2000 ppmV (calibrated 0.1 to 700 ppmV); opt. inlet to 300 barg
Accuracy
±0.1 ppmV (<1 ppmV) / ±10 %; internal NPL/NIST self-calibration
Communication
7″ touchscreen, SD card, 2× 4–20 mA / 1–5 V, Modbus RTU (RS485/USB), Modbus TCP

In stock

Model
Michell QMA601 Moisture in CO2
Range
1 to 1000 ppmV in CO2 (trend to 2000 ppmV); pressure 2 barg
Accuracy
±1 ppmV (1–10 ppmV) / ±10 % (10–2000 ppmV); CO2 cal NPL/NIST
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays

In stock

Model
Michell QMA601
Range
0.1 to 2000 ppmV (calibrated 0.1 to 700 ppmV); pressure 2 barg
Accuracy
±0.1 ppmV (<1 ppmV) / ±10 % of reading; NPL/NIST self-cal
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays

In stock

Model
Michell QMA601-LR
Range
0.02 to 100 ppmV (20 ppbV LoD; trend to 2000 ppmV); 2 barg
Accuracy
±0.03 ppmV or ±10 % of reading; NPL/NIST traceable
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays