Showing 1–12 of 192 resultsSorted by popularity

In stock

Model
Michell Condumax II + OptiPEAK TDL600
Range
Moisture 1–1000 ppmV (TDLAS); HCDP up to Δ 55 K depression (Dark Spot); to 100 barg
Accuracy
Moisture ±1 ppmV / ±3 %; Hydrocarbon DP ±0.5 °C; pressure ±0.25 % FS
Communication
4–20 mA outputs, alarm relays, RS485 Modbus RTU, 4.3″ LCD & VFD

In stock

Model
Michell QMA401
Range
0.1 to 2000 ppmV (calibrated 0.1 to 700 ppmV); opt. inlet to 300 barg
Accuracy
±0.1 ppmV (<1 ppmV) / ±10 %; internal NPL/NIST self-calibration
Communication
7″ touchscreen, SD card, 2× 4–20 mA / 1–5 V, Modbus RTU (RS485/USB), Modbus TCP

In stock

Model
Michell Promet I.S.
Range
-100 to +20 °Cdp; operating pressure up to 45 MPa (450 barg); up to 20 % H2
Accuracy
±1 °Cdp (-60 to +20 °Cdp) / ±2 °Cdp (-100 to -60 °Cdp); pressure ±0.25 % FS
Communication
2.8″ LCD, 3× 4–20 mA, RS485 Modbus RTU, 4 alarm relays

In stock

Model
Michell Multi-Channel Process Monitor
Range
Up to 6 independent channels: moisture in gas/liquid & O2 (% / ppmV)
Accuracy
Resolution down to 0.001 ppmV, 0.1 °Cdp, 0.01 % / 0.5 ppmV O2; dynamic P comp
Communication
7″ touchscreen, 3× 4–20 mA/ch, RS485 Modbus RTU, Ethernet Modbus TCP/IP, 32 GB SD

In stock

Model
Michell Promet EExd
Range
-120 to +30 °Cdp (1 ppbV to 30,000 ppmV); pressure 30 to 138 barg
Accuracy
±1 °Cdp (-59.9 to +20 °Cdp) / ±2 °Cdp (-100 to -60 °Cdp); pressure ±0.25 % FS
Communication
Through-glass VFD, 2× 4–20 mA/ch, RS485 Modbus RTU, 2 relays/ch

In stock

Model
Michell QMA601 Moisture in CO2
Range
1 to 1000 ppmV in CO2 (trend to 2000 ppmV); pressure 2 barg
Accuracy
±1 ppmV (1–10 ppmV) / ±10 % (10–2000 ppmV); CO2 cal NPL/NIST
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays

In stock

Model
Michell QMA601-LR
Range
0.02 to 100 ppmV (20 ppbV LoD; trend to 2000 ppmV); 2 barg
Accuracy
±0.03 ppmV or ±10 % of reading; NPL/NIST traceable
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays

In stock

Model
Michell QMA601
Range
0.1 to 2000 ppmV (calibrated 0.1 to 700 ppmV); pressure 2 barg
Accuracy
±0.1 ppmV (<1 ppmV) / ±10 % of reading; NPL/NIST self-cal
Communication
7″ through-glass LCD, 2× 4–20 mA / 1–5 V, Modbus RTU/TCP, 4 relays

In stock

Model
Michell OptiPEAK TDL600
Range
1 to 1000 ppmV (up to 100 barg); up to 20 % hydrogen
Accuracy
±1 ppmV or ±3 % of reading; repeatability ±0.5 ppmV or ±1.5 %
Communication
3× 4–20 mA out, 2× 4–20 mA in, RS485 Modbus RTU, 3 relays, 4.3″ LCD

In stock

Model
Michell S8000 -100
Range
-100 to +20 °C frost/dew point (to 13.8 ppbV); pressure up to 1.6 bara
Accuracy
±0.1 °C; reproducibility ±0.15 °Cfp at -100 °Cfp; stability ±0.1 °C
Communication
2× 0/4–20 mA, Modbus RTU (USB), opt. RS485/RS232/TCP Ethernet, 8 GB SD, 5.7″ LCD

In stock

Model
Michell S8000 RS
Range
-90 / -80 to +20 °C frost/dew point (to 95.4 ppbV); pressure up to 10 barg
Accuracy
±0.1 °C; stability ±0.05 °C; reproducibility ±0.05 / ±0.025 °Cdp
Communication
2× 0/4–20 mA, Modbus RTU (USB), Modbus TCP/IP (Ethernet), 8 GB SD, 5.7″ LCD

In stock

Model
Michell S8000
Range
-60 to +40 °Cdp; pressure 0 to 1 barg (LP) / 0 to 20 barg (HP)
Accuracy
±0.1 °Cdp; reproducibility ±0.05 °C; optional Pt100 ±0.1 °C
Communication
2× 4–20 mA / 0–1 V, Modbus RTU (USB), Modbus TCP (Ethernet), SD card, 5.7″ display